ces_ca001053.jpg
MITSUBISHI 1100A UPS

©
ces_ca048039.jpg
Floor Space Saving, Single Input, Suitable for any 208/120V Direct Output Distribution.
Where future upgradeability (capacity or redundancy of UPS with long battery runtime) and high quality output power is primary requirement.
ces_ca048033.jpg ces_ca001033.jpg ces_ca001032.jpg ces_ca001052.jpg

ces_ca001030.jpg


TM
MITSUBISHI DIAMONDPLUS 1100A UPS CONFIGURATIONS & OPTIONS
Capacity 
kVA/kW
Battery System
UPS Dimensions
Total UPS Weight
Part Number
External
SMB
600 & 480V
Application
10kVA/9kW
(Capacity)
208/120V-
208/120V
Internal: 18 Minutes
External: Up to 480 Min.
(Option by CES)
19.7"W x 27.0"D x 55.1"H
685 Lbs
(With Internal Batteries)
M1100A-A-10-208-208-1B
 
 
20kVA/18kW
(Capacity)
10kVA/9kW
(N+1 Redundancy)
208/120V-208/120V 
Internal: 5 Minutes
External: Up to 300 Min.
(Option by CES)
19.7"W x 27.0"D x 55.1"H
730 Lbs
(With Internal Batteries) 
M1100A-A-20-208-208-1B 
10kVA/9kW
(Capacity)
208/120V-208/120V 
Internal: None
(Empty Tray)
External: Up to 480 Min.
(Option by CES) 
19.7"W x 27.0"D x 55.1"H
300 Lbs
(With Empty Battery Trays) 
M1100A-A-10-208-208 
 20kVA/18kW
(Capacity)
10kVA/9kW
(N+1 Redundancy)
208/120V-208/120V 
Internal: None
(Empty Tray)
External: Up to 300 Min.
(Option by CES) 
19.7"W x 27.0"D x 55.1"H
340 Lbs
(With Empty Battery Trays) 
M1100A-A-20-208-208 
10kVA/9kW
(Capacity)
208/120V-
208/120V
 
External Only: Up to 480 Minutes  
19.7"W x 27.0"D x 55.1"H
300 Lbs
(UPS ONLY) 
M1100A-B-10-208-208 
 
 
 
 
 20kVA/18kW
(Capacity)
10kVA/9kW
(N+1 Redundancy)
208/120V-208/120V 
 
External Only: Up to 300 Minutes 
19.7"W x 27.0"D x 55.1"H
340 Lbs
(UPS ONLY) 
M1100A-B-20-208-208 
 
 
 
 
30kVA/27kW
(Capacity)
20kVA/18kW
(N+1 Redundancy)
208/120V-208/120V 
External Only: Up to 300 Minutes 
19.7"W x 27.0"D x 55.1"H
380 Lbs
(UPS ONLY) 
M1100A-B-30-208-208 
 
 
40kVA/36kW
(Capacity)
30kVA/27kW
(N+1 Redundancy)
208/120V-208/120V 
External Only: Up to 240 Minutes  
19.7"W x 27.0"D x 55.1"H
420 Lbs
(UPS ONLY) 
M1100A-B-40-208-208 
50kVA/45kW
(Capacity)
40kVA/36kW
(N+1 Redundancy)
208/120V-208/120V 
External Only: Up to 240 Minutes 
19.7"W x 27.0"D x 55.1"H
420 Lbs
(UPS ONLY) 
M1100A-B-50-208-208 
ces_ca048022.jpg ces_ca048021.jpg ces_ca048020.jpg ces_ca048019.jpg ces_ca048018.jpg ces_ca048017.jpg ces_ca048016.jpg ces_ca048009.jpg ces_ca001007.jpg ces_ca001005.jpg ces_ca001004.jpg ces_ca001003.jpg

> 1100A SERIES BROCHURE

> 1100A SERIES SPECIFICATIONS

> 1100A SERIES FACILITY PLANNING

> 1100A SERIES MANUAL

> 1100A SERIES SERVICE MANUAL

> 1100A SERIES DRAWINGS

> 1100A UPS MONITORING

> CASE STUDY

> PICTURES & VIDEOS






|
|
|
|
|
CORPORATE
PRODUCTS
MITSUBISHI UPS
SOLUTIONS
SUPPORT
CONTACT US
|
ces_ca001001.jpg ces_ca001011.jpg